ccs: tristar: get scaling on launch
this should also make Tristar::new return an error if the port exists but doesn't have a modbus device there - previously this would fail later when it times out reading registers
This commit is contained in:
parent
20a7ad6ddd
commit
c28802c3d8
1 changed files with 14 additions and 10 deletions
|
@ -52,7 +52,7 @@ pub struct Tristar {
|
|||
modbus: tokio_modbus::client::Context,
|
||||
charge_state_gauges: ChargeStateGauges,
|
||||
consecutive_errors: usize,
|
||||
scaling: Option<Scaling>,
|
||||
scaling: Scaling,
|
||||
}
|
||||
|
||||
#[derive(Debug, Clone, Copy)]
|
||||
|
@ -261,7 +261,7 @@ impl Tristar {
|
|||
) -> eyre::Result<Self> {
|
||||
let slave = tokio_modbus::Slave(DEVICE_ID);
|
||||
|
||||
let modbus = match transport {
|
||||
let mut modbus = match transport {
|
||||
crate::config::Transport::Serial { port, baud_rate } => {
|
||||
let modbus_serial = tokio_serial::SerialStream::open(
|
||||
&tokio_serial::new(port, *baud_rate).timeout(std::time::Duration::from_secs(3)),
|
||||
|
@ -274,6 +274,13 @@ impl Tristar {
|
|||
}
|
||||
};
|
||||
|
||||
let scaling = {
|
||||
let scaling_data = modbus
|
||||
.read_holding_registers(0x0000, RAM_DATA_SIZE + 1)
|
||||
.await??;
|
||||
Scaling::from(&scaling_data)
|
||||
};
|
||||
|
||||
let charge_state_gauges = ChargeStateGauges::new(friendly_name);
|
||||
|
||||
Ok(Self {
|
||||
|
@ -281,14 +288,14 @@ impl Tristar {
|
|||
modbus,
|
||||
charge_state_gauges,
|
||||
consecutive_errors: 0,
|
||||
scaling: None,
|
||||
scaling,
|
||||
})
|
||||
}
|
||||
|
||||
pub async fn refresh(&mut self) -> eyre::Result<crate::controller::CommonData> {
|
||||
let new_state = self.get_data().await?;
|
||||
|
||||
self.scaling = Some(new_state.scaling);
|
||||
self.scaling = new_state.scaling;
|
||||
self.consecutive_errors = 0;
|
||||
BATTERY_VOLTAGE
|
||||
.with_label_values(&[&self.friendly_name])
|
||||
|
@ -343,7 +350,7 @@ impl Tristar {
|
|||
}
|
||||
|
||||
pub async fn set_target_voltage(&mut self, target_voltage: f64) -> eyre::Result<()> {
|
||||
let scaled_voltage: u16 = self.scale_voltage(target_voltage)?;
|
||||
let scaled_voltage: u16 = self.scale_voltage(target_voltage);
|
||||
self.modbus
|
||||
.write_single_register(TristarRamAddress::VbRefSlave as u16, scaled_voltage)
|
||||
.await??;
|
||||
|
@ -356,11 +363,8 @@ impl Tristar {
|
|||
Ok(())
|
||||
}
|
||||
|
||||
fn scale_voltage(&self, voltage: f64) -> eyre::Result<u16> {
|
||||
let Some(scaling) = &self.scaling else {
|
||||
return Err(eyre::eyre!("no scaling data present"));
|
||||
};
|
||||
Ok(scaling.inverse_voltage(voltage))
|
||||
fn scale_voltage(&self, voltage: f64) -> u16 {
|
||||
self.scaling.inverse_voltage(voltage)
|
||||
}
|
||||
|
||||
async fn get_data(&mut self) -> eyre::Result<TristarState> {
|
||||
|
|
Loading…